Features
Construction/Installation ▪ Shallow Single Wall New Construction. ▪ Housing adjusts in frame to accommodate up to 1 1/4" ceiling thickness. Suitable for T-grid and drop ceiling applications. ▪ High strength hanger bars can easily be nailed to joists. ▪ Designed for ceiling plenums where 2x6 joists or taller are used. Steel housing for greater heat dissipation. Stamped Galvanized steel frame.
Junction Box ▪ Positioned to accommodate straight conduit runs. ▪ Seven (7) 1/2" trade size conduit knockouts, Four (4) 3/4" knockouts with pry-out knockout slots. ▪ Four (4) Romex pry-outs with strain relief. See installation sheet for detailed information
Hanger Bars / New Construction ▪ Pre-installed hanger bars with True Nail facilitate easy installation in regular lumber, engineered lumber, and laminated beams. Maximum hole cut-out is 4 1/4". ▪ Integral T-bar slots for easy installation in T-bars. Spans up to 24" and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction. Integral leveling flange allows for single-person installation while aligning the housing with joists.
Electrical ▪ Input Voltage: 120VAC. Output Voltage: 12V AC. Max Wattage: 50W. Thermally protected against improper lamping.
Dimmability ▪ Based on lamp selection. Magnetic Transformer dims with MLV type dimmers. Lamp may affect dimmability.
Compatible Trims ▪ Compatible with - ELCO 4" MR16 Trims and designed for use with 12V MR16 50W Max GU/GX5.3 MR16 LED/Halogen Bulbs: Sold Separately!
Listing ▪ UL Listed for Damp Locations. UL Listed Wet Location with select trims. ▪ Airtight per ASTM E-283. Install a JA8 2016-E Lamp/Luminaire For Title 24 Compliance ▪ UL Listed For Feed Through.
|
|
|
|
|
|
|