Features
Construction ▪ Single wall Listed for direct contact with installation, for use in IC and non-IC conditions ▪ Housing adjusts in frame to accommodate up to 1 1/4" ceiling thickness. ▪ Aluminum housing for greater heat dissipation. Stamped galvanized steel frame ▪ Driver mounted on junction box for cooler LED operation. Designed for shallow ceiling plenums where 2x4 joists or taller are used
Junction Box ▪ Positioned to accommodate straight conduit runs. ▪ Two 1/4" trade size pry-out knockouts with conduit fitting provided ▪ Suitable for T-grid and drop ceiling applications. See installation sheet for detailed information
Hanger Bars / New Construction ▪ Pre-installed hanger bars with True Nail easy installation in regular lumber, engineered lumber, and laminated beams. ▪ Integral T-bar slots for easy installation. Spans up to 24" and can be repositioned 90°. Score lines allow for tool-free hanger bar size reduction
Electrical ▪ Driver connects to 120V only or 120/277V power supply. High Efficiency driver with a power factor > 0.9.
Dimmability ▪ Works with 120V Triac and ELV type dimmers, and 120-277V 0-10V dimming. Dims down to 10%. For full list of dimmers, refer to Compatible Dimmer List.
Compatible Trims ▪ Compatible with - E210C18, E213C18, E214C18, E215C18, E218C18, E219C18
Listing ▪ UL Listed for Wet Location, UL Listed for Feed Through ▪ Meets restricted airflow requirements (per ASTM-283) ▪ UL Listed for Direct Contact with Insulation and Combustible Materials. CA Title 24 Compliant
|
|
|
|
|
|
|